C#和倍福PLC之间的通讯控制

1.新建项目并引用TwinCAT动态链接库

2.引用类,并编写倍福控制的相关对象

1 1 using System; 2 2 using System.Collections; 3 3 using System.Collections.Generic; 4 4 using System.Linq; 5 5 using System.Text; 6 6 using TwinCAT.Ads; 7 7 8 8 9 9 namespace Project_V1._001_Data 10 10 { 11 11 public class Beckhoff_PLC 12 12 { 13 13 14 14 15 15 #region 基本对象定义 16 16 /// <summary> 17 17 /// 创建Ads对象 18 18 /// </summary> 19 19 public static TwinCAT.Ads.TcAdsClient _adsClient = new TcAdsClient(); 20 20 21 21 /// <summary> 22 22 /// 定义连接PLC的AMSNetID 23 23 /// </summary> 24 24 public static string string_AmsNetID = "192.168.0.122.1.1"; 25 25 26 26 27 27 /// <summary> 28 28 /// 定义连接PLC的端口号 29 29 /// TwinCAT2,端口号801;TwinCAT3,端口号为851 30 30 /// </summary> 31 31 //public static int iPort = 801; 32 32 public static int iPort = 851; 33 33 34 34 35 35 /// <summary> 36 36 /// PLC连接成功的标志 37 37 /// </summary> 38 38 public static bool bConnectToBeckhoffOK = false; 39 39 40 40 41 41 public static ArrayList notificationHandles = new ArrayList(); 42 42 #endregion 43 43 44 44 #region 函数定义 45 45 /// <summary> 46 46 /// 连接到PLC 47 47 /// </summary> 48 48 public static void ConnectPLC() 49 49 { 50 50 try 51 51 { 52 52 //_adsClient.Connect(string_AmsNetID, iPort); 53 53 _adsClient.Connect(iPort); 54 54 bConnectToBeckhoffOK = true; 55 55 56 56 } 57 57 catch 58 58 { 59 59 bConnectToBeckhoffOK = false; 60 60 } 61 61 } 62 62 63 63 /// <summary> 64 64 /// 读取double类型的变量,非实时刷新 65 65 /// </summary> 66 66 /// <param name="PlcVariableName"></param> 67 67 /// <returns></returns> 68 68 public static double ReadDouble(string PlcVariableName) 69 69 { 70 70 double dResult = 0; 71 71 try 72 72 { 73 73 int iHandleTemp = _adsClient.CreateVariableHandle(PlcVariableName); 74 74 dResult = (double)(_adsClient.ReadAny(iHandleTemp, typeof(double))); 75 75 _adsClient.DeleteVariableHandle(iHandleTemp); 76 76 } 77 77 catch { return 0; } 78 78 return dResult; 79 79 } 80 80 81 81 /// <summary> 82 82 /// 根据PLC变量名,写PLC变量 83 83 /// </summary> 84 84 /// <param name="PlcVariableName"></param> 85 85 /// <param name="dResult"></param> 86 86 public static void WriteVariable(string PlcVariableName, double dResult) 87 87 { 88 88 try 89 89 { 90 90 int iHandleTemp = _adsClient.CreateVariableHandle(PlcVariableName); 91 91 _adsClient.WriteAny(iHandleTemp, dResult); 92 92 _adsClient.DeleteVariableHandle(iHandleTemp); 93 93 } 94 94 catch { } 95 95 } 96 96 97 97 /// <summary> 98 98 /// 根据PLC变量名,写PLC变量 99 99 /// </summary> 100100 /// <param name="PlcVariableName"></param> 101101 /// <param name="dResult"></param> 102102 public static void WriteVariable(string PlcVariableName, bool bResult) 103103 { 104104 try 105105 { 106106 int iHandleTemp = _adsClient.CreateVariableHandle(PlcVariableName); 107107 _adsClient.WriteAny(iHandleTemp, bResult); 108108 _adsClient.DeleteVariableHandle(iHandleTemp); 109109 } 110110 catch { } 111111 } 112112 113113 114114 #endregion 115115 116116 } 117117 }

 3.主程序中直接调用倍福控制类

using System;using System.Collections;using System.Collections.Generic;using System.Linq;using System.Text;using TwinCAT.Ads;

namespace Project_V1._001_Data{    public class Beckhoff_PLC    {       
        #region 基本对象定义        /// <summary>        /// 创建Ads对象        /// </summary>        public static TwinCAT.Ads.TcAdsClient _adsClient = new TcAdsClient();
        /// <summary>        /// 定义连接PLC的AMSNetID        /// </summary>        public static string string_AmsNetID = "192.168.0.122.1.1";     
        /// <summary>        /// 定义连接PLC的端口号        /// TwinCAT2,端口号801;TwinCAT3,端口号为851        /// </summary>        //public static int iPort = 801;         public static int iPort = 851;

        /// <summary>        /// PLC连接成功的标志        /// </summary>        public static bool bConnectToBeckhoffOK = false;

        public static ArrayList notificationHandles = new ArrayList();        #endregion
        #region 函数定义        /// <summary>        /// 连接到PLC        /// </summary>        public static void ConnectPLC()        {            try            {                //_adsClient.Connect(string_AmsNetID, iPort);                _adsClient.Connect(iPort);                bConnectToBeckhoffOK = true;                           }            catch            {                bConnectToBeckhoffOK = false;            }        }
        /// <summary>        /// 读取double类型的变量,非实时刷新        /// </summary>        /// <param name="PlcVariableName"></param>        /// <returns></returns>        public static double ReadDouble(string PlcVariableName)        {            double dResult = 0;            try            {                int iHandleTemp = _adsClient.CreateVariableHandle(PlcVariableName);                dResult = (double)(_adsClient.ReadAny(iHandleTemp, typeof(double)));                _adsClient.DeleteVariableHandle(iHandleTemp);            }            catch { return 0; }            return dResult;        }
        /// <summary>        /// 根据PLC变量名,写PLC变量        /// </summary>        /// <param name="PlcVariableName"></param>        /// <param name="dResult"></param>        public static void WriteVariable(string PlcVariableName, double dResult)        {            try            {                int iHandleTemp = _adsClient.CreateVariableHandle(PlcVariableName);                _adsClient.WriteAny(iHandleTemp, dResult);                _adsClient.DeleteVariableHandle(iHandleTemp);            }            catch { }        }
        /// <summary>        /// 根据PLC变量名,写PLC变量        /// </summary>        /// <param name="PlcVariableName"></param>        /// <param name="dResult"></param>        public static void WriteVariable(string PlcVariableName, bool bResult)        {            try            {                int iHandleTemp = _adsClient.CreateVariableHandle(PlcVariableName);                _adsClient.WriteAny(iHandleTemp, bResult);                _adsClient.DeleteVariableHandle(iHandleTemp);            }            catch { }        }

        #endregion
    }}

点赞
收藏

评论区

加载中...

相关推荐

MySQL:[Err] 1292 - Incorrect datetime value: ‘0000-00-00 00:00:00‘ for column ‘CREATE_TIME‘ at row 1

文章目录问题用navicat导入数据时,报错:原因这是因为当前的MySQL不支持datetime为0的情况。解决修改sql\mode:sql\mode:SQLMode定义了MySQL应支持的SQL语法、数据校验等,这样可以更容易地在不同的环境中使用MySQL。全局s

Oracle 分组与拼接字符串同时使用

SELECTT.,ROWNUMIDFROM(SELECTT.EMPLID,T.NAME,T.BU,T.REALDEPART,T.FORMATDATE,SUM(T.S0)S0,MAX(UPDATETIME)CREATETIME,LISTAGG(TOCHAR(

MySQL部分从库上面因为大量的临时表tmp_table造成慢查询

背景描述Time:20190124T00:08:14.70572408:00User@Host:@Id:Schema:sentrymetaLast_errno:0Killed:0Query_time:0.315758Lock_

皕杰报表之UUID

​在我们用皕杰报表工具设计填报报表时,如何在新增行里自动增加id呢?能新增整数排序id吗?目前可以在新增行里自动增加id,但只能用uuid函数增加UUID编码,不能新增整数排序id。uuid函数说明:获取一个UUID,可以在填报表中用来创建数据ID语法:uuid()或uuid(sep)参数说明:sep布尔值,生成的uuid中是否包含分隔符'',缺省为

2020年前端实用代码段,为你的工作保驾护航

有空的时候,自己总结了几个代码段,在开发中也经常使用,谢谢。1、使用解构获取json数据let jsonData  id: 1,status: "OK",data: 'a', 'b';let  id, status, data: number   jsonData;console.log(id, status, number )

GitHub 上有哪些适合新手跟进的优质项目?

!(https://oscimg.oschina.net/oscnet/011f28e3bc332010e1442e6c00ed344805d.jpg)点击上方“迈微电子研发社”,选择“星标★”公众号重磅干货,第一时间送达!(https://oscimg.oschina.net/oscnet/cd44ba75f

C#和倍福PLC之间的通讯控制 - HelloWorld